FUTURE IS OUR FIRST PRIORITY

NATALLY Radiant Infant Warmer

Creating a safe, comfortable, and nurturing environment for newborns is essential, both in delivery rooms and during subsequent intensive care. This includes ensuring optimal temperature control, minimizing noise and light disturbances, and providing state-of-the-art medical equipment designed to meet the delicate needs of infants.

The goal is to create a space where newborns can feel secure, promoting their health and development while also offering parents peace of mind during these critical early moments.

Key Features

  • Preheating mode, manual mode and body temperature mode
  • 90° rotation of the emitter to both sides
  • Electrical bed tilting
  • Positionable 9” colour LCD monitor
  • Vital sings monitoring by Masimo
  • Integrated weighing scale
  • Height-adjustable chassis with two-side control
  • Phototherapeutic module
  • Wide selection of accessories

Technical Specifications

TECHNICAL SPECIFICATIONS: Radiant Warmer Natally RW-610
Unit type identification RW-610
Power voltage 110 / 120 /127 / 230 V, 60,50 Hz
Power input 700 VA
Dimensions Height without height adjustable chassis: 1 895 mm
Height with height adjustable chassis: 1 835 - 2 035 mm
Length: 1 020 mm
Width: 580 mm
Mattress: 730 x 485 x 40 mm
Sound pressure level (audible alarm signal) 66 – 72 dBA (measurement radius of 1 m)
Maximum input via auxiliary sockets 100 W
Weight Natally with fixed height chassis: 92 kg
Natally with height adjustable chassis: 102 kg
Rotating of the emitter 180° (by 90° anti- and clockwise)
Electric bed positioning 12° (Trendelenburg, anti-Trendelenburg)
TEMPERATURE MODE
Manual mode (adjustment range) 1 – 100% heating performance, 1% steps
Range of displayed performance values 0 - 100 %
Body temperature mode (adjustment range) 34,0 °C - 37,0 °C, in steps of 0,1 °C
37,1 °C - 38,0 °C, in steps of 0,1 °C
Body temperature adjustment over 37.0 °C Only upon special operator’s intervention after the >37 °C key is pressed
Range of displayed temperature values 10,0 °C - 45,0 °C
Preheating mode Allows immediate care of the newborn child after delivery
APGAR SCORE MODE
Range of the measured time max. 99 min
Range of displayed values 0 - 99 min
Accuracy of time measurement ±0,1 s
Resolution After 1 s
WEIGHING MODE
Scales range max. 7 kg
Range of displayed weight values 0 - 7 kg
Scale accuracy ±2 g ±1 digit (from 0 kg to 1 kg)
±5 g ±1 digit (from 1 kg to 3 kg)
±10 g ±1 digit (from 3 kg to 7 kg)
Resolution 1 g
Records Weight trends, weight increments

Technical Documentation